2M-308017-011C Built-In Single Well Modular Warmer w/T-Stat Control
5
INSTALLATION
3. For “top-mounted” warmers (i.e. warmers mounted from above
the counter top):
a. Verify that provided sealants are applied to the underside
of the warmer top ange prior to setting the unit into the cutout.
b. After installation, verify that the tabs on the Wellsloks are turned
out to lock the warmer into the counter
c. Apply a thin bead of food-grade silicone sealant around the ange
to seal it to the counter.
d. Wellslok extension kits are available for installing warmers in
counter tops where the standard Wellslok would not normally
reach. The extension kit will adapt to counter tops up to 1¾” thick.
ELECTRICAL INSTALLATION
1. Refer to the product nameplate. Verify the electrical service
power. Voltage and phase must match the nameplate
specications. Wiring the warmer to the wrong voltage can
severely damage the unit or cause noticeably decreased
performance.
2. Available electrical service amperage must meet or exceed the
specications listed on the specication sheet provided with the
warmer.
3. Warmer and control unit must be connected to an appropriate
building ground. Ground connection will be marked “GND” or
” “ .
NOTE: Wire gauge, insulation type and temperature rating , as
well as type, size and construction of conduit, must meet or exceed
applicable specications of local codes and of the National
Electrical Code.
PLUMBING INSTALLATION
For use in the State of Massachusetts, this appliance must be
installed in compliance with Massachusetts Fuel Gas and
Plumbing Code CMR 248.
1. IMPORTANT: All plumbing installations must be performed by
a qualied plumber.
2. For units equipped with a DRAIN LINE: Some jurisdictions may
require an approved air gap or other back-ow prevention device
in the drain. It is the responsibility of the plumber to determine
such requirement, to provide and properly install the required
device.
NOTE: Damage caused
by leaks due to improper
installation is NOT covered by
warranty.
CAUTION:
SHOCK HAZARD
The ground lug of this
appliance must be connected
to a suitable building ground.
IMPORTANT:
Contact a licensed electrician
to install and connect electrical
power to the appliance.
IMPORTANT:
Damage due to being
connected to the wrong
voltage or phase is NOT
covered by warranty.
IMPORTANT: Electrical
installation other than as
specied on the specication
sheet will void the UL listing,
and may void the warranty.
NOTE: Plumb connections
must be made in compliance
with all Federal, State and
Local Plumbing Codes and
Ordinances.