SEASONAL CLEANING 
If the A/C will not be used for a long time:   
l  Pull out the water wedge to drain.   
l  Run the A/C in fan mode for 2H till its inside is dry.   
l  Turn off the A/C and unplug.   
l  Wash the filter screen and reassemble it.   
l  Dismantle the exhaust duct and keep it properly.   
l  Cover the A/C with a plastic bag and place it at a dry place.   
COMMON FAILURES AND DIAGNOSIS 
INTELLIGENT ERROR DETECTION 
Error-detecting code 
Multi-functional defection 
E1 
Error of the coil’s temperature sensor   
E2 
Error of indoor temperature sensor 
E4 
Anti-freezing  protection:  temperature  of  the  coil  is  too 
low  and  the  whole  A/C  is  off.  When  temperature 
excesses 8℃, the protection is released and previous 
working state is recovered.   
FUSE PARAMETERS 
Specification: Φ5×20mm 
Voltage: 250VAC 
Current: 3.15A 
TROUBLE-SHOOTING 
In case of any of the following trouble, please contact professional maintenance personnel 