SEASONAL CLEANING
If the A/C will not be used for a long time:
l Pull out the water wedge to drain.
l Run the A/C in fan mode for 2H till its inside is dry.
l Turn off the A/C and unplug.
l Wash the filter screen and reassemble it.
l Dismantle the exhaust duct and keep it properly.
l Cover the A/C with a plastic bag and place it at a dry place.
COMMON FAILURES AND DIAGNOSIS
INTELLIGENT ERROR DETECTION
Error-detecting code
Multi-functional defection
E1
Error of the coil’s temperature sensor
E2
Error of indoor temperature sensor
E4
Anti-freezing protection: temperature of the coil is too
low and the whole A/C is off. When temperature
excesses 8, the protection is released and previous
working state is recovered.
FUSE PARAMETERS
Specification: Φ5×20mm
Voltage: 250VAC
Current: 3.15A
TROUBLE-SHOOTING
In case of any of the following trouble, please contact professional maintenance personnel