Step 5 - Lay the screed layer
Heated screeds will expand and contract slightly during use therefore
expansion joints may also be required. As per: ISO 11855-5, an expansion
joint plan (including type and place of joint) shall be drawn up by the
building planner.
A joint shall be applied above a building joint. The oor screed shall be
separate from rising elements (border joints, e.g. walls doorways etc.).
The determination of joint width, joint distance and joint areas depends
on type of binder, oor covering geometry of the area, use of area and
temperature change.
1
Before installing any screed, oor nish, adhesives or glues over
the system, the installation requirements of each must be checked
to ensure compatibility with underoor heating.
Underoor heating performs the most eciently with conductive,
low resistance oor nishes such as stone and tiles.
Screed Type
Minimum thickness
(mm)
Standard
Traditional
cementitious
sand/cement
75 (65) BS 8204-1
Traditional
calcium sulfate
40 CIRIA Report 184
Pumpable
self-smoothing
calcium sulfate
40 (35) BS 8204-7
Pumpable
self-smoothing
cementitious
40 (35) BS 8204-7
Table 1 - Screed types and minimum thicknesses
Table 1 shows dierent screed materials used and minimum
thicknesses required for use with underoor heating systems.
Domestic measurements are in brackets. This table is for
guidance only, screed layers used over Warmup Nexxa must be
chosen and installed in line with the latest edition of building
regulations and standards.