Lay the oor covering adhering
to the ooring manufacturers
instructions�
Ensure any oor coverings,
underlays and adhesives used are
suitable for use with underoor
heating at the intended
operational temperatures and
conditions.
1
All oor nishes
Step 6 - Floor covering
Before installing any oor nish, adhesive or underlay over the
screed layer, the installation requirements of each must be
checked to ensure compatibility with underoor heating.
Underoor heating performs the most eciently with conductive,
low resistance oor nishes such as stone and tiles. The maximum
thermal resistance of the oor should not exceed 0.15 [m²K/W].
1
Approved oor covering
2
Perimeter strip
To allow for dierential
movement between nished
oor level and walls
3
Screed layer
4
16mm PE-RT pipe
5
Metro rail
6
Vapour control layer
To prevent water ingress
7
Insulation layer
8
Damp proof membrane
To prevent water ingress
9
Concrete suboor