Kit for use with the 4iE
Troubleshooting
Due to the large number of dierent boiler systems and wiring plans in use, Warmup cannot
guarantee compatibility with a particular system. Compatible with Combi and System boilers
with 230VAC, volt-free or low voltage input up to 3A. The boiler manufacturer or manual will
be able to conrm if the boiler is compatible with this.
Is the +Kit compatible with
this heating system?
How do I re-pair the
system?
4iE display is blank
4iE displays “er1 amb”
If the wireless connection is lost the LED on the Boiler Receiver will ash RED. If it does not
auto reconnect, press and hold the power button on the Boiler Receiver for 6 seconds. Remove
the 4iE from the Power Base and using a device such as a paper clip press the pairing button
as shown on page 15. The light on the Boiler Receiver will ash GREEN twice to indicate a
successful connection.
Note: You can manually override the system, should the wireless connection fail by pressing
the power button on the Boiler Receiver as shown on page 17.
1. Check that the display/standby brightness is not on the lowest setting, “0”. To access
display/audio settings rst press the standby button at the bottom of the 4iE. Then press
menu, settings and display/audio settings & display brightness.
2. Verify that power is going to the 4iE. Check that the Power Base is plugged in.
+
22
The system type on initial setup should be set to “Central Heating”. If you are using the
Thermostat with a central heating system you will not have a oor sensor installed. Switch
the Thermostat to air mode
>settings >heating preference >control >air/oor