Warmup Forte handleiding
Handleiding
Je bekijkt pagina 4 van 28

4
Please also read the full instructions that follow this section.
Installation summary
• The suboor must be clean, level,
smooth, dry, frost-free, solid,
suitably weight-bearing and
dimensionally stable.
• Lay a damp proof membrane
over the suboor to prevent
water ingress.
• Install perimeter strip around the
perimeter of the room to allow for
dierential movement between
nished oor level and walls.
• Lay insulation board over the
membrane. Insulation should be
chosen and installed in line with
building regulations.
• Lay a vapour control layer over
the insulation to prevent water
ingress.
• Following the structural engineers
design, install the reinforcement
mesh taking care not damage the
damp proof membrane.
• Install the pipe in line with the projects working drawings. It is
recommended the pipe is installed using a spiral pattern to achieve an
even surface temperature and a high heat output.
• Install the pipe at the necessary spacing for the heat output required.
Secure the pipe to the reinforcement mesh with cable ties at
approximately 500 mm intervals.
1 2
3 4
5
SR2
2 m < 5 mm