Troubleshooting
ISSUE 1 - Running out of pipe/excess pipe leftover
PROBLEM SOLUTION
When laying the pipe, incorrect pipe
spacing has been used.
The pipe will have to be
installed again at the correct
spacing as per your design
layout�
ISSUE 2 - Floor overheating at ow and returns to manifold
PROBLEM SOLUTION
As the pipes reach the manifold they
are tightly packed together which will
give a higher heat output.
The pipes will need to be
insulated using 15mm conduit
or pipe lagging.
ISSUE 3 - Excessive/insucient heat output
PROBLEM SOLUTION
Incorrect water temperature
Refer to System Performance
chart to calculate the required
water temperature