Step 3 - Lay the pipe
Install the sensor, at least 300 mm into the heated area it will be
controlling. It should be located centrally between the closest parallel
runs of pipe and not in an area inuenced by other heat sources.
The sensor can be secured to the reinforcement mesh with cable ties
as shown
DO NOT tape over the sensor tip it must be in full contact
with the screed layer.
Measure and cut the pipe so that it reaches both the ow and return
ports on the manifold.
Refer to the manifold manual for detailed information on mounting,
pressure testing and commissioning.