Appendix 1.0 - Thermostat use cases
No.
Reg.
Mode
Probe
P1
(5 & 6)
Probe
P2
(6 & 7)
Control
Limit
Sensor
Use Case
1
OFF
OFF OFF
Internal
Air Sensor
None
Thermostat in room
air temperature schedule
no oor limit
2
ON OFF
P1
Floor Sensor
None
Thermostat in/out of room
oor temperature schedule
oor limit
3
Internal
Air Sensor
Thermostat in room
oor temperature schedule
air limit
4
P1
Air Sensor
None
Thermostat out of room
air temperature schedule
no oor limit
5 OFF ON
Internal
Air Sensor
P2
Floor Limit
Thermostat in room
air temperature schedule
oor limit
6
ON ON
P1
Floor Sensor
P2
Floor Limit
Thermostat in/out of room
oor temperature schedule
oor limit
7
P1
Air Sensor
P2
Floor Limit
Thermostat out of room
air temperature schedule
oor limit
8
ON
OFF OFF Reg.
None
Thermostat in/out of room
regulator schedule
no limit
9
Internal
Air Sensor
Thermostat in room
regulator schedule
air limit
10 OFF ON Reg.
P2
Floor Limit
Thermostat in/out of room
regulator schedule
oor limit
Hydronic underoor heating