Warmup 7iE Matter handleiding

22 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 19 van 22
19
EcoDesign compliance information card
Room temperature control
power consumption
The control must include an o mode and/or a
standby mode, in addition to an idle mode. The power
consumption must comply with requirements for each
mode where applicable.
In o
mode
P
o
≤ 0.5W
In standby
mode
P
sm
≤ 0.5W
P
dsm
≤ 1.0W
(if control has an active display in
standby mode)
P
nsm
≤ 2.0W
(if control has a network connection
in standby mode)
In idle
mode
P
idle
≤ 1.0W
P
nidle
≤ 3.0W
(if control has a network connection)
Type of heat output/room
temperature control
TD Electronic room temperature
control plus day timer
TW Electronic room temperature
control plus week timer
Other control options
f2 Open window detection
f3 Distance control option
f4 Adaptive start control
f7 Self-learning functionality
f8 Control accuracy
This control has the following control functions and exceeds the EcoDesign requirements for
electric underoor local space heaters and towel rails as set out in Commission Regulation
(EU) 2024/1103: TW (f2/f3/f4/f8)
The Warmup 7iE includes these control function codes and power consumptions:
Code of
temperature
control (TC)
Control functions
f1 f2 f3 f4 f5 f6 f7 f8
Type of
temperature
control
Single stage, no temperature control NC
Two or more manual stages, no temperature control TX
Mechanic thermostat room temperature control TM
Electronic room temperature control TE
Electronic room temperature control plus day timer TD
Electronic room temperature control plus week timer TW
Control
functions
Presence detection 1
Open window detection 2
Distance control option 3
Adaptive start control 4
Working time limitation 5
Black bulb sensor 6
Self-learning functionality 7
Control accuracy with CA < 2 Kelvin and CSD < 2 Kelvin 8
Control function codes (Required to be in manual as part Regulation (EU) 2024/1103)
Warmup plc T: 0345 345 2288 F: 0345 345 2299 www.warmup.co.uk
704 Tudor Estate n Abbey Road n London n NW10 7UW n UK
Warmup GmbH n Ottostraße 3 n 27793 Wildeshausen n DE
Thermostat model
7iE (7iE-01)
Control function code
TW (f2/f3/f4/f8)
Power consumption
O mode Standby mode Idle mode
P
o
≤ 0.5W P
sm
≤ 0.5W P
dsm
≤ 1.0W P
nsm
≤ 2.0W P
idle
≤ 1.0W P
nidle
≤ 3.0W

Bekijk gratis de handleiding van Warmup 7iE Matter, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkWarmup
Model7iE Matter
CategorieThermostaat
TaalNederlands
Grootte4000 MB