Step 9 - Troubleshooting
Troubleshooting
Due to the large number of dierent boiler systems
and wiring plans in use, Warmup cannot guarantee
compatibility with a particular system. Compatible
systems include Combi and System boilers with 230VAC,
volt-free or low voltage input up to 3A. The boiler
manufacturer or manual will be able to conrm if your
boiler is compatible.
Is the 5iE compatible with
this heating system?
How do I pair the system
again?
Thermostat display is
blank
The system type on initial setup should be set to
“Conventional”. If you are using the Thermostat with a
conventional system (central heating) you will not have
a oor sensor installed. Switch the Thermostat to air
mode by pressing menu, settings, heating preference,
control air/amb and switch to air.
Thermostat displays “er1
amb”
If the connection drops the LED on the Boiler Receiver
will ash RED. Remove the Thermostat from the Power
Base and using a device such as a paper clip press the
pairing button as shown on page 13. The light on the
Boiler Receiver will turn o to indicate a successful
connection.
Note: You can manually override the system to get the
heating to work should the wireless connection fail by
pressing the power button on the Boiler Receiver as
shown on page 8.
1. Check that the display/standby brightness is not
on the lowest setting, “0”. To access display/audio
settings rst press the standby button at the bottom
of the Thermostat. Then press menu, settings and
display/audio settings & display brightness.
2. Verify that power is going to the Thermostat. Check
that the Power Base is plugged in.
20