45
4 Technical data
4.1 Data
Model
K118
K128 / K128 F
K138 / K138 F
Nominal heat output
kW
6
7
Emission flow with coal
g/s
10,8 / 9,9
10,5 / 11,5
Flue gas temperature at exhaust socket
0
C
240
250 / 270
Required pressure at NHC
Pa
12
12
Room heat capacity* continuous heating
periodic heating
m
3
165 / 95 / 65
116 / 69 / 47
210 / 120 / 82
148 / 86 / 59
Flue gas connection diameter
Ø mm
120
120
Dust (based on 13% O
2
)
mg/m³
≤ 40
≤ 40
CO (based on 13% O
2
)
mg/m³
1070 / 1409
1224 / 1179
CO (based on 13% O
2
)
%
0,09 / 0,11
0,10 / 0,10
Efficiency
%
76,3 / 76,8
77,5 / 73,4
NHC = Nominal Heat Capacity
* according to DIN 18893 Tab. 2 at good / less good / poor heating conditions
All information provided by the exhaust gas values are based on the EN 13240 under stationary
laboratory conditions