Je bekijkt pagina 36 van 116

36
Correct
Incorrect
min.50cm
min.5m
below
5m
Lower as the
top of the roof
min.30cm
Tightening cross section
of the chimney because
the smoke tube is
pushed into the chimney
too much
Obstruction ,
because the
smoke tubes are
led as facing each
other
Faulty draught,
because a
fire-place’s
door (not in
use) is open
False air because of
an open tube joint
False air,
because of a
leaky tube joint
False air,
because a open
fire-place door
Bekijk gratis de handleiding van Wamsler K118, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.