Should the height be less then the stove must be connected to a vertical flue pipe which is
not less than 1 m in length.
Connecting to a flue of less than 4 m is not permitted by law.
As the chimney stack draught depends on a number factors, a side vent device can be
inserted at least 40 cm above the base to avoid overloading the fire and to avoid soot build
up. Side air devices can only be introduced into rooms where burning stoves are installed.
If there are a number of fire points in different rooms with a common chimney stack then
they are not permitted.
In addition to the points listed here, notice should be taken of DIN EN 13384, DIN
18160, EN 1856-2 and EN 15287.
The necessary combustion air can only be fed to the stove and the flue gases removed
through the chimney if an air exchange of at least 0.8 times per hour is guaranteed (doors,
windows, air duct).
Before connecting the stove seek advice from a chimney sweep.
2.3 The heating stove for open and closed systems
Heating stove model K148/K148F is only allowed to operate with heat sink in closed sys-
tems according to EN 12828. If it is connected to an open system then our guarantee for
corrosion damage becomes invalid.
Heating stove model K148/K148F, is suitable for open systems if a heat exchanger for the
heat sink is incorporated.
Further directions on central heating units are given in section 4.
Heating stoves for solid fuel can only be operated in closed systems with a flow independ-
ent heat sink with the safety valve mounted above the stove set at 2.5 bar.
The heat sink has to work in conjunction with the heat exchanger with large fires and low
heat loss of heating and domestic water which does not exceed the permissible highest
value of pressure in the heating pocket. The safety valve must therefore be checked regu-
larly. This is done by depressing the red button for a short time. Water must pass through
the valve while this is happening.
ATTENTION
The stove may only be heated up (even in testing) if:
- it is connected to a central heating system completely filled with water and
- The functioning of the thermal safety valve and the safety valve have been estab-
lished and inspected, if it connected to a closed system.
2.4 Spacer connection and accessories
If the stove is to be integrated in a fitted kitchen, then the interface to a floor mounted cup-
board with a counter has to have a spacer connection which can be supplied by the fac-
tory. The available spacer connections are tested to EN with the stove and comply with
building regulation requirements relating to fire protection.