11 FUNCTION TEST AFTER THE REPAIR
After all repairs, the AquaCoat system must be checked for safe condition before
recommissioning. The necessary scope of inspection and testing depends on the repair
carried out and must be documented by the repair sta.
The system must not be lled with liquid for this function check.
Activities Aid tools
1. Check connections Visual check
Check all product screw connections.
Check all air connections.
All electrical cables must be rmly secured.
"Safety-relevant check"
2. Check grounding connection Multimeter
Measure resistance between grounding terminal and:
Handle of the gun (metal connections)
Pneumatic door switch
Product hose connection
Grounding switch
Set value: respective maximum 10 Ω.
Check visually the black grounding band in the cabinet door including
the black grounding bolt.
"Safety-relevant check"
3. Check potential equalization Multimeter
Measure resistance between leakage resistance and:
Grounding point
Pump support
Potential equalization line at the pump
Connection terminal for product tank
Set value: respective maximum 10 Ω.
4. Connect the device
Connect grounding cable.
Main tap closed.
Connect air supply (mains pressure 0.8 MPa; 8 bar; 116 psi).
Connect the mains.
5. Adjust alarm horn Hexagon socket wrench
3 mm; 0.12 inches
(only for level indication with alarm horn)
Loosen control unit and remove from mounting (see Chapter 10.5).
Switch air on.
Set alarm horn regulator to normal volume.
Switch air o and remount control unit in cabinet.