OPERATING MANUAL
VERSION 02/2018 ORDER NUMBER DOC 2366717
B_04791
SW2
1Nm
X
6
7
3
X = 122 ± 0.1 mm; 4.8032 ± 0.004 inch
Valve rod unit
Set length adjusting measure X
with withdrawal nut (7) and then
fasten the threaded pin (6) using
an Allen wrench SW2.
B_04372
0.5 Nm
SW6
0.8 Nm +0.1 Nm
SW5
2
1
4
5
8
9
10
8
7
11
2
2
9
2
2
Wear gloves!
The outside thread of the packing (9) must be free
of lacquer.
Valve rod unit (8) and packing (9):
- grease,
- slide together,
- screw together (10).
Grease clamping screw (1) and mount using
assembly tool (5).
Insert spring (4).
Coat the hollow section
with a brush.
Note: avoid the pin and hexagon.
(sparingly)
Only as required (if the rod seal was removed):
Press in rod seal (11). In the process, press only
on the lowest area of the rod seal.