Grounding scheme (example)
B_05904
Rmax.< 1 M
Conveyor
Spraying stand
Floor, static dissipative
Signal groundSignal ground
Work piece
Minimum cable cross-section
AquaCoat cabinet 4 mm²; AWG 12
Conveyor 16 mm²; AWG 6
Spray booth 16 mm²; AWG 6
Spraying stand 16 mm²; AWG 6
Safe operation of the AquaCoat system is only guaranteed with a grounding connection.
Connect all ground cables using a short and direct route.
Tank
All paints, ushing agents and waste tanks have to be made of metal.
All tanks in the cabinet must be connected to the potential equalization. All further
tanks must be grounded.
6.6 SAFETY CHECKS