Wagner GM 5020EAW handleiding
Handleiding
Je bekijkt pagina 15 van 136

15
OPERATING MANUAL
VERSION 02/2018 ORDER NUMBER DOC 2366717
Ensure that there are no ignition sources such as naked ames, sparks, glowing wires,
or hot surfaces in the vicinity. No smoking.
Ensure that the pipe joints, hoses, equipment parts and connections are permanently,
technically leak-proof:
– Periodic preventative maintenance and service (replacing hoses, checking tightness
strength and connections, etc.)
– Regular monitoring of leaks and defects via visual inspection and odor testing,
e.g., daily before commissioning, at the end of work or weekly.
In the event of defects, immediately bring the device or system to a stop and arrange
to have repairs carried out immediately.
4.1.3 PERSONNEL QUALIFICATIONS
Hazard due to incorrect use of device!
Risk of death due to untrained personnel.
Ensure that the operating personnel has been instructed by the operator in accordance
with the operating manual and the operating instructions. The device must only
be operated, maintained and repaired by trained personnel. Refer to the operating
instructions for information about the required personnel qualications.
4.2 SAFETY INSTRUCTIONS FOR STAFF
Always follow the information in this manual, particularly the safety instructions and
the warning instructions.
Always follow local regulations concerning occupational safety and accident prevention.
Hazard due to high-voltage eld!
Danger to life from malfunction of active implants.
Persons belonging to a risk group according to EMF guideline 2013/35/EU
(e.g., carriers of active implants), must not enter the high-voltage area.
4.2.1 PERSONAL SAFETY EQUIPMENT
Hazard due to dangerous uids or steam!
Serious or fatal injuries due to inhalation, swallowing or contact with the skin or eyes.
When preparing or working with paint and when cleaning the device, follow the
working instructions of the manufacturer of the lacquers, solvents, and cleaning
agents being used.
Take the specied protective measures. In particular wear safety goggles, protective
clothing and gloves, as well as hand protection cream if necessary.
Use a mask or breathing apparatus if necessary.
For sucient health and environmental safety: Operate the device in a spray booth or
on a spraying wall with the ventilation (extraction) switched on.
Wear suitable protective clothing when working with hot products.
Bekijk gratis de handleiding van Wagner GM 5020EAW, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Wagner |
| Model | GM 5020EAW |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 17100 MB |