Wagner GM 5020EAW handleiding
Handleiding
Je bekijkt pagina 11 van 136

11
OPERATING MANUAL
VERSION 02/2018 ORDER NUMBER DOC 2366717
2.4 PROCESSIBLE WORKING MATERIALS
Water-dilutable lacquers are in principle divided into 3 groups:
Non-ignitable lacquers
Hard to ignite lacquers
Ignitable lacquers
Only non-ignitable liquid spray products can be processed with the present spray system.
The specic resistance of the spray product must be between 0.5 kΩ cm and 1 MΩ cm.
Assign group
Basically, the lacquer manufacturer determines in which group a spray product is to be classied.
1. Request the group classication from the lacquer manufacturer or lacquer supplier.
2. Only if no information can be obtained from the lacquer manufacturer and the lacquer
supplier, the following recipe can be used to determine whether the spray product is
non-ignitable:
63 49
37 51
Where:
Weight percent
Water
Liquid organic phase; main components: Higher glycol esters in a mixture
with max. 1:1 of propanol.
Solid organic phase; main components: Binding agents and pigments.
Such lacquers behave like water in liquid form (liquid phase) and in sprayed form.
Cleaning and ushing agents
Cleaning and ushing agents must also align with this category.
Example of non-ignitable liquid:
No more than 35 weight percent, 1:1 butylglycol/n-propanol, rest water.
Please contact your local WAGNER dealer and the paint manufacturer if you encounter
application problems.
2.5 MISUSE
Misuse can lead to physical injury and/or property damage!
Special attention must be paid that:
No dry coating products, e.g., powder are processed.
No food, medicine or cosmetics are processed.