Wachendorff WDGA 58V handleiding
Handleiding
Je bekijkt pagina 80 van 82

Technical Manual
WDGA with CANopen Interface
8 - Setting-up the encoder
© Wachendorff Automation GmbH & Co. KG
69
8.12.2 Restoring default parameters from EEPROM
Restoring default settings by using object 1011h:
Sub-Index
Access mode
Description
0
co
Number of objects
1
wo
Restore all parameters
2
wo
Restore communication objects
3
wo
Restore application objects
4
wo
Restore manufacturer objects
Table 8.77: Restoring parameters
• To restore the default settings the "ASCII" value "load" (in
hex: 64616F6Ch) has to be written to the dedicated sub-index
of the object.
• Attention: The baudrate and node-ID settings, as well as the
customer data object, will not be restored!