Wachendorff MA964802 handleiding
Handleiding
Je bekijkt pagina 9 van 54

User manual - MA964802 9  
Alarm mode
Absolute/Threshold, Band with instantaneous/
delayed/retentive action and by digital input/commu-
nication failure / activation from serial communication
Slave COM2 serial port Modbus RTU slave protocol
USB port
Virtual Com Port with Modbus RTU slave protocol. 
Memory card connection for parameter confi uration
5  Dimension and installation
45 x 91 mm
Frontal panel cut-out
TEMPERATURE
A1 A2
571.0 °C
PRESSURE
HUMIDITY
571 mBar
57.1 rH%
96 mm
48 mm
18
12
1711
1610
159
14
8
137
SUPPLY
24...230V
AC/DC
6
5
4
3
2
1
Q1
2A 230V
Resistive
1/8HP
Q2
2A 230V
Resistive
1/8HP
Memory Card
48 mm
5
10
Spessore suggerito
2÷15 mm 
Suggested thickness
USB
Memory Card  USB
DI.1
+24Vdc
DI.2
COM1 B
DI.3
COM1 A
COM2 B COM2 A
COM1 C
AI.1
COM2 C
(optional)
Art.Nr.: SFUR0USB
Bekijk gratis de handleiding van Wachendorff MA964802, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Wachendorff | 
| Model | MA964802 | 
| Categorie | Niet gecategoriseerd | 
| Taal | Nederlands | 
| Grootte | 4022 MB | 








