Wachendorff MA964802 handleiding

54 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 9 van 54
User manual - MA964802 9
Alarm mode
Absolute/Threshold, Band with instantaneous/
delayed/retentive action and by digital input/commu-
nication failure / activation from serial communication
Slave COM2 serial port Modbus RTU slave protocol
USB port
Virtual Com Port with Modbus RTU slave protocol.
Memory card connection for parameter confi uration
5 Dimension and installation
45 x 91 mm
Frontal panel cut-out
TEMPERATURE
A1 A2
571.0 °C
PRESSURE
HUMIDITY
571 mBar
57.1 rH%
96 mm
48 mm
18
12
1711
1610
159
14
8
137
SUPPLY
24...230V
AC/DC
6
5
4
3
2
1
Q1
2A 230V
Resistive
1/8HP
Q2
2A 230V
Resistive
1/8HP
Memory Card
48 mm
5
10
Spessore suggerito
2÷15 mm
Suggested thickness
USB
Memory Card USB
DI.1
+24Vdc
DI.2
COM1 B
DI.3
COM1 A
COM2 B COM2 A
COM1 C
AI.1
COM2 C
(optional)
Art.Nr.: SFUR0USB