8.5 Acquisition of potentiometer limits
This function allows you to activate an "on eld" calibration procedure of the
minimum and maximum limits for the potentiometer input.
This function is enabled for conguration in the “Potentiom. input” section at
the item Acquisition. Once acquisition has been enabled and you have exited
confi uration, the following screen appears automatically.
Min
Acquired value
Max
0
100
Esc
48
At this point, proceed as follows:
Set the potentiometer at the position you wish to associate to the
Minimum
value
.
Press
to acquire the position and to store the value. The
Acquired value
will indicate the
Min.
value showing that the command has been executed.
Set the potentiometer at the position you wish to associate to the
Maximum
value
.
Press
to acquire the position and to store the value. The
Acquired value
will indicate the
Max.
value showing that the command has been executed.
At this point, the potentiometer acquisition procedure is nished; check that the
potentiometer position and the
Acquired value
correspond.
Press
Esc
to exit the procedure.