b. Elements heat.
2) K1-N.C. contacts open.
3) K1-1 N.C. contacts open (prevents
timer from energizing during Pre-Heat.
G. Steamer reaches 175 °F.
1) Hold thermostat opens and relay K1
coil is de-energized.
a. K1-3 N.O. contacts close and
remove line voltage to heating
element assembly.
b. K1-1 and K1-2 N.C. contacts
return to close condition.
NOTE: Steamer will maintain Hold temperature until
a cook time is dialed on timer, door is opened, or
power switch is turned off.
2) Set cook timer to desired time.
NOTE: Timer motor will not run when the hold
thermostat (3TAS) is below 175 °F.
a. Timer contacts close, timer motor
is energized, and timing down
begins.
NOTE: Additional time can be set, or the cook timer
can be turned off throughout the cooking cycle. If
turned to off, steamer reverts to hold temperature.
b. Cook light (3LT, red) comes on.
c. Temperature controller energized
and evaluates input from the
thermocouple.
a) If temperature is below set
point, temperature controller
internal N.O. contacts close
and energize regulating
contactor (2CON) coil thru
K1-2 N.C. contacts.