5. Record the temperature reading when regulating
contactor opens.
6. Using the elevation table, compare the recorded
temperature to the temperature listed for the
specific elevation.
NOTE: Use temperature scale on control dial plate for
reference only. The scale represents dial turns in 1°F
increments, not the actual temperature. When
calibrating, use the recorded temperature taken from
thermocouple.
ELEVATION (FT) TEMPERATURE (°F)
Sea Level 210
1,000 208
2,000 206
3,000 204
4,000 202
5,000 200
6,000 198
7,000 196
8,000 195
9,000 or above 194
A. If the set point temperature of the control is
correct, no adjustment is necessary.
B. If the set point temperature of the control is
not correct, adjust the temperature control.
1) Turn temperature control dial
clockwise to increase temperature or
counterclockwise to decrease
temperature.
NOTE: During temperature control adjustment,
display will blink on/off. When display reverts to a
steady image, that displayed temperature set point
has been "locked in" to memory.
Fig. 59
C24EO SERIES ELECTRIC COUNTERTOP STEAMERS - SERVICE PROCEDURES AND ADJUSTMENTS
Page 27 of 43 F25386 Rev. C (0421)