A carbon block filter system should always be
used to remove Chlorine and Chloramine. If a
water softener is used, a carbon block is still
required. Check with your local water treatment
specialist for proper sizing and replacement
intervals for the carbon block cartridge.
3
If the Chlorides exceed 30 ppm and the oven is
used more than 8 hours during the day in steam
or combination mode, the cavity will require
rinsing every 8 hours. Failure to do so will result
in corrosion and rusting of the oven cavity and
interior parts. A Reverse Osmosis water treatment
system can be installed to eliminate chlorides
from the water and reduce the hardness.
Preventative washing and rinsing may be needed
more than once a day to prevent compounding of
contaminants inside cavity.
4
Total Chlorine of 4.0 ppm is the max limit for the
building water supply. A carbon block filter must
still be used to remove all Chlorine and
Chloramines from the water. Failure to do so will
result in corrosion and rust in the cooking cavity,
which is not covered under warranty.
SPECIFICATIONS
Electric
120VAC/60HZ/1 phase (proper ground required).
NOTE: Do not connect this unit to a ground-fault
circuit-interrupter (GFCI) 125-volt, single-phase, 15-
and 20-ampere receptacle. Electronic burner ignition
systems are prone to nuisance tripping and possible
ignition failure.
Gas Pressures
Gas Supply Pressure*
Natural 7.0" - 10.5" W.C.
Propane 11.0" - 13" W.C.
* Maximum supply pressure can not exceed 14"
W.C. (1/2 psig).
Gas Manifold Pressure
Natural 2.5" W.C.
Propane 10.0" W.C.
Blower Air Pressure
NOTE: Blower settings
are only made on units up
to serial number
463024849, soloranics
burner is not adjustable.
0.35" W.C. - Cold
.45" W. C. - Hot
Burner Pressure**
Hot .4" to .5" WC.
Cold .33" to .35" WC
** The blower air pressure reading will be higher
when the steam generator is hot vs cold. If the
steam generator has been on for 15 minutes or
more, the operating condition is considered hot.
24 volt transformer needs to be disconnected
when checking blower speed settings.
TOOLS
Standard
• Standard set of hand tools.
• VOM with minimum of NFPA-70E CATIII 600V,
UL/CSA/TUV listed. Sensitivity of at least 20,000
ohms per volt and the ability to measure DC
micro amps. Meter leads must also be rated at
CAT III 600V.
• Temperature tester (thermocouple type).
• Manometer.
• Gas leak detection equipment. (Must be resistant
to reaction of propane gas).
• Clear silicone sealant.
Special
• Requires U-inclined (Grainger P/N 3T294) or
digital (Grainger P/N 4JZ78) manometer capable
of reading in 0.01" WC increments. Used for
measuring gas manifold pressures and blower
air pressures.
• RTV 109 for securing gasket to door.
• Loctite® 271.
• Screwdriver, 1/8 X 4 cabinet tip.
• Scale Release PN 854893-13 (14 oz).
• SPS620V Red Filter Head (Kit P/N
854306-00013).
• SMF620 Black Head (Kit P/N 857487-00620).
• Combustion analyzer needed for Soloronics
burner assembly set up procedures.
• Pressure Gauge Assembly
• Low Pressure Gauge - 0 to 5 psi.
recommended (Grainger Part No. 2C641).
• Water Hose Coupling - swivel type
(Grainger Part No. 4KG87).
• Reducer Bushing (Grainger Part No.
6MN61).
C24GA AND C24DA SERIES CONVECTION STEAMER - GENERAL
F35425 Rev. E (0119) Page 8 of 65