AUTOMATIC IGNITION SYSTEMS
NOTE: Only for units with adjustable pilot burner.
ADJUSTABLE PILOT BURNER (1)
SOLARONICS BURNER ASSEMBLY (1) NON-
ADJUSTABLE PILOT
When the main power switch is turned on and the water level is above LLCO, the ignition control module is energized
with 24 volts between terminals five and six. High voltage is sent from terminal nine to the spark electrode and an
output of 24 volts is sent from terminals two and three to the pilot coil in the combination valve, allowing gas to flow
to the pilot. The sparking will continue for 90 seconds or until the flame sensor has confirmed that an adequate pilot
flame is present.
Once the pilot flame is confirmed, a 24 volt output from terminal one will be sent to the gas combination control
valve.
TERMINAL NO. DESCRIPTION
1
Voltage (24 VAC) will be present on MV terminal #1 with the pilot sensing electrode
sensing an adequate pilot flame. This output will remain present as long as the pilot
flame remains adequate.
2 Common MV/PV.
3
The Pilot Voltage (24 VAC) will be present on terminal #3 at the instant an input voltage
is supplied to the module. This voltage will remain present on terminal #3 providing an
adequate pilot flame is established within 90 seconds. In the event that an adequate
pilot flame is not established within 90 seconds this output voltage will drop out.
4 Ground (burner).
5 Ground (24 VAC Neutral).
6 24 VAC Input.
8 Flame Sensor.
9 Flame Sensor.
PREVIOUS PRODUCTION SHOWN
C24GA AND C24DA SERIES CONVECTION STEAMER - SERVICE PROCEDURES AND ADJUSTMENTS
F35425 Rev. E (0119) Page 34 of 65