B. Slowly turn the adjustment screw
counterclockwise until main gas valve
energizes then add 1/2 turn to the
adjustment. The screw head should not
extend out past the screw housing.
1) If gas valve energizes, proceed to step
5.
2) If gas valve does not energize, check
the following:
a. Remove the lead wires from the
switch and verify with a meter that
the switch contacts are closing
with the blower on. If necessary,
continue to turn the adjustment
screw several turns
counterclockwise to close the
switch contacts.
b. If the switch contacts are not
closing, turn the power switch off,
remove the pressure switch from
the manifold and check the air
orifice for debris build up and
clogging. If debris is found, clean
it away from the orifice.
c. Replace the orifice, pressure
switch and connect the lead wires
to the switch. Turn the power
switch on and adjust the pressure
switch again as outlined in steps
4A and 4B. Verify the pilot gas
valve is energizing. d. If the pilot
gas valve is not energizing and
power is available to the pressure
switch, turn the power switch off.
Replace with a new air pressure
switch and adjust the switch as
outlined from step 3 thru the end
of this procedure.
5. Restart the ignition sequence by turning the
power switch off, waiting 3 seconds, then back
on. .
A. Listen or use a meter for gas pilot ignition to
verify operation.
1) If gas pilot ignition is successful, listen
for main gas burner ignition to verify
operation.
B. Verify the pilot and main burner both ignite
in succession.
1) Restart the ignition sequence by
rapidly turning the power switch off
then back on. A rapid switching is
needed to keep the generator from
starting automatic blowdown.
C. Listen for main gas burner ignition to verify
operation
PILOT BURNER ADJUSTMENT
(ONLY UNITS WITH ADJUSTABLE
PILOT)
Shut off the gas before servicing the
unit and follow lockout / tagout
procedures.
NOTE: Only for units with adjustable pilot burner.
C24GA AND C24DA SERIES CONVECTION STEAMER - SERVICE PROCEDURES AND ADJUSTMENTS
Page 27 of 65 F35425 Rev. E (0119)
Bekijk gratis de handleiding van Vulcan C24DA10, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Vulcan |
Model | C24DA10 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 16865 MB |