3. Replace malfunctioning flame sensor or pilot
assembly.
4. Reverse procedure to install a new flame sensor
or pilot assembly.
5. Check for proper operation.
BLOWER CONTROL RELAY (K3)
Shut off the gas before servicing the
unit and follow lockout / tagout
procedures.
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
NOTE: Starting with production Serial No. 463008610
and higher will have blower control relay (K3) installed.
C24GA 6&10 production gas steamers will begin
using a blower control relay (K3) to carry blower motor
current instead of the operating pressure switch
contacts.
K3 relay must be installed into earlier production units
that are having a Solaronics burner assembly
installed.
NOTE: K3 relay has been used since April 2013 on
units with serial number 463008610 and higher.
ADJUSTABLE PILOT BURNER (1)
Fig. 40
SOLARONICS BURNER ASSEMBLY (1) NON-
ADJUSTABLE PILOT
Fig. 41
1. Remove CABINET BASE FRONT PANEL.
2. Locate blower control relay (K3) in front of
steamer base.
3. Note and disconnect lead wires from relay
terminals.
4. Remove (2) mounting screws.
Fig. 42
5. Reverse procedure to install and check for proper
operation.
C24GA AND C24DA SERIES CONVECTION STEAMER - REMOVAL AND REPLACEMENT OF PARTS