Open Top - Pilot access can be reached under the grate support beam running from left to right.
Manual Griddle Pilot access can be reached under the griddle plate through the slotted
opening in the manifold cover near the burner valve knob.
4. Turn the burner valve ON to the desired heat.
5. If burners fail to light, turn off all valves, and call an authorized installation or service person.
6. To shut down, turn the burner valve to the OFF position.
7. For complete shut down, turn all burner valves to the OFF position. Turn off main gas supply.
Thermostatic Griddle
1. Turn the thermostat to the OFF position.
2. Turn the main gas supply valve to the ON position.
3. Depress and hold the red button on the safety valve and light the pilot through the slotted opening
in the manifold cover near the burner valve knob.
4. Hold red button down for at least 30 seconds.
5. When button is released, pilot should remain lit.
6. Pilot flame must be high enough to heat thermocouple.
7. Turn thermostat to desired temperature setting.
8. If ignition fails, turn the control knob to OFF. Wait 5 minutes and repeat the above procedure.
DO NOT attempt to relight pilot without waiting 5 minutes.
9. For temporary or nightly shutdown, turn control knob to OFF position.
10. For complete shutdown, turn control knob to OFF position, and turn off main gas supply.
Hot Top, Griddle/Broiler
1. Turn the main gas supply valve to the ON position.
2. Light all standing pilots.
Hot Top Pilot access can be reached under the hot top through the slotted opening in the
manifold cover near the burner valve knob.
Griddle/Broiler Pilot access can be reached under the griddle through the broiler opening.
The pilot burner is on the bottom left side of the griddle/broiler burner.
3. Turn the burner valve ON to the desired heat.
4. If burners fail to light, turn off all valves, and then call an authorized installation or service person.
5. To shut down, turn the burner valve to the OFF position.
6. For complete shutdown, turn all burner valves to OFF position. Turn off main gas supply.