Failure Display and Inspection
26
Failure code Problem Solution
Reinsert the connection between the display board
and the power board.
Replace the power board.
Wait for the temperature of ceramic plate return to
normal.
Touch “ON/OFF” button to restart unit.
Ceramic plate temperature sensor
failure--open circuit.
E1
Ceramic plate temperature sensor
failure- -short circuit.
E2
Ceramic plate temperature sensor
failure
Eb
High temperature of ceramic plate
sensor.
E3
Wait for the temperature of IGBT return to normal.
Touch “ON/OFF” button to restart unit.
Check whether the fan runs smoothly;
if not , replace the fan.
E6
High temperature of IGBT.
Reinsert the connection between the display board
and the power board.
Replace the power board or the display board.
Communication error.
U1
The induction hob is equipped with a self diagnostic function. With this test the technician is able to
check the function of several components without disassembling or dismounting the hob from the
working surface.
Troubleshooting
1) Failure code occur during customer using & Solution;
Replace the power board.
Temperature sensor of the IGBT
E4
failure --open circuit.
Temperature sensor of the IGBT
E5
failure --short circuit
Please inspect whether power supply is normal.
Power on after the power supply is normal.
Supply voltage is below the rated
voltage.
E7
Supply voltage is above the rated
voltage.
E8
No Auto-Recovery