UL GUIDANCE FOR PRODUCTS WITH R290 REFRIGERANT CONTINUED
WARNING
Decommissioning
Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and
all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being
carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of recovered
refrigerant. It is essential that electrical power is available before the task is commenced.
A. Become familiar with the equipment and its operation.
B. Isolate the system electrically.
C. Before attempting the procedure, ensure that:
i. Mechanical handling equipment is available, if required, for handling refrigerant cylinders;
ii. All personal protective equipment is available and being used correctly;
iii. The recovery process is supervised at all times by a competent person;
iv. Recovery equipment and cylinders conform to the appropriate standards.
D. Pump down refrigerant system, if possible.
E. If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the
system.
F. Make sure that cylinder is situated on the scales before recovery takes place.
G. Start the recovery machine and operate in accordance with instructions.
H. Do not overfill cylinders (no more than 80 % volume liquid charge).
I. Do not exceed the maximum working pressure of the cylinder, even temporarily.
J. When the cylinders have been filled correctly and the process completed, make sure that the cylinders and
the equipment are removed from site promptly and all isolation valves on the equipment are closed o.
K. Recovered refrigerant shall not be charged into another REFRIGERATING SYSTEM unless it has been cleaned
and checked.
L. Labelling: Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant.
The label shall be dated and signed. For appliances containing FLAMMABLE REFRIGERANTS, ensure that
there are labels on the equipment stating the equipment contains FLAMMABLE REFRIGERANT.
FUNCTION & PURPOSE
These units are intended to keep food at proper serving temperatures in locations with ambient temperatures below 86 °F (30 °C). Using them
in locations with warmer temperatures will take units out of NSF compliance. Modifying refrigeration parameters may void the warranty.
Hot Mode is not intended to cook raw food or to reheat prepared food. Cold Mode is not intended to cool or chill food and Frozen Mode is not
intended to cool or freeze food. Food must be prepared and placed into the food station at proper serving temperatures. Refrigerated/Cold and
Frozen Modes are best used for holding periods up to four hours. For best performance, stainless steel containers are recommended.
Units are not intended for household, industrial, or laboratory use
RECORD YOUR SERIAL NUMBER
The serial number for this equipment can be found on the rating plate located below the well, near the power cord. To aid in future
communication about your product, please record the serial number in the space below.
Rating Plate
Serial Number:

Bekijk gratis de handleiding van Vollrath FC-HCF-03120-AD-FF, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkVollrath
ModelFC-HCF-03120-AD-FF
CategorieNiet gecategoriseerd
TaalNederlands
Grootte1078 MB