Vocopro FeatherAmp FA-500 handleiding

20 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 17 van 20
There is no power
• Check the power cable connection both at the mains and the Feather Amp. Also make sure that the Feather Amp
is congured for local power (115V/230V).
One channel is not working
• Check the source audio device. Is it congured correctly? Are both channels working? If using RCA cables, are
both cables working and corrected properly?
• Is the unit in bridge mode? Refer to section 4.2.
Sound is distorted
• This is most likely occurring at the source device. Make sure the signal is set to an appropriate level. Are there
clip LEDs lighting on the source device?
Thermal LED is lit or unit has shut down
• The unit has exceeded it maximum operating temperature. Check the impedance of connected speakers. Is the
total load lower than 3Ω? Refer to section 3.3.
• Is the Feather Amp properly ventilated? The fan should not be blocked. NOTE: The fan is not always running. It is
only activated when the unit requires cooling.
Overload LED is lit or unit has shut down
• The incoming current has exceeded 30A. Check the speaker cables. Is there a short? If using bare wire for
speaker connection, is a strand of wire making contact with another speaker output contact? Refer to section 3.3.
• Check the speaker impedance load. Is the total load less than 3Ω? Refer to section 3.3.
Troubleshooting 6.0
17

Bekijk gratis de handleiding van Vocopro FeatherAmp FA-500, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkVocopro
ModelFeatherAmp FA-500
CategorieNiet gecategoriseerd
TaalNederlands
Grootte2165 MB