Vimar RS05 handleiding
Handleiding
Je bekijkt pagina 28 van 32

26
10 - Troubleshooting:
Problem Cause Solution
The automatic gate system does not work No mains supply
Blown fuses
Control and safety inputs not working
Check the power line switch
Replace the fuses with others of the same value
Check the diagnosis LEDS (stop, STPA and photo
must be on)
You cannot save the remote controls Safety devices open
Batteries of the remote control discharged
Remote control not compatible with the first one
saved
Reached memory saturation
Check the diagnosis LEDS (stop, STPA and photo
must be on)
Replace the batteries
The first saved remote control configures the
control panel to save only rolling-code remote
controls or only dip-switch remote controls.
Delete at least one remote control or add an
external receiver (maximum capacity 200 remote
controls)
The remote control does not work Batteries of the remote control discharged Replace the batteries
You cannot enter travel programming Safety devices open Check the diagnosis LEDS (stop, STPA and photo
must be on)
As soon as the gate starts it stops and
reverses
Motor torque not sufficient Increase the force with the trimmer TR2
During slowdown, the gate stops and
reverses
Slowdown speed too low Increase the value of trimmer TR3
The gate does not stop with the limit
switches tripping, where applicable
The magnetic sensor cannot read the magnet Move the magnet near to the sensor
Check the LEDS of the limit switches.
Check dip switch number 2-1 for limit switch
presence and dip switch 2-2 for direction of gate
opening.
Bekijk gratis de handleiding van Vimar RS05, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Vimar |
Model | RS05 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 2892 MB |