24
Dip switch number Status of dip switch Description
DIP 1-1 OFF Automatic closing function off
DIP 1-1 ON Automatic closing function on
DIP 1-2 OFF Condominium function on (during gate opening it is not possible to stop the movement with the
remote control or AP/CH inputs)
DIP 1-2 ON With each command the gate: opens, stops, closes, stops
DIP 1-3 OFF Pre-flashing off
DIP 1-3 ON Pre-flashing on, before the gate moves the flashing light comes on for 3 seconds
DIP 1-4 OFF STPA input as internal photocell
DIP 1-4 ON STPA input as sensitive edge
DIP 1-5 OFF Photo-test function off
DIP 1-5 ON Photo-test function on (photocell checking with each command) see paragraph 4.6.3
DIP 1-6 OFF Second radio channel associated with pedestrian gate opening
DIP 1-6 ON Second radio channel associated with activation for 1 second of 2can output (terminal 3 and 4)
DIP 1-7 OFF Sensitive edge with normally closed contact
DIP 1-7 ON Resistive sensitive edge, normally open contact with balancing resistance of 8.2 K Ohm in parallel
DIP 1-8 OFF Close immediately function off
DIP 1-8 ON Enables the close immediately function (the photocell tripping takes the automatic closing time to 5
seconds, upon its disengagement)
DIP 2-1 OFF not used
DIP 2-1 ON not used
DIP 2-2 OFF For opening the gate to the left
DIP 2-2 ON For opening the gate to the right
8 Programmable functions:
The table shows the functions that can be activated via the dip switches, the control unit reads the dip switches with the gate stationary on closing:
EN
Bekijk gratis de handleiding van Vimar RS05, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Vimar |
Model | RS05 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 2892 MB |