5.14 Two-way Crossover
The two-way crossover consists of a High Pass Filter and a Low Pass Filter, which can
divide the input signal up into 2 discreet audio bands (Low and High).
As shown below, pressing the 2-WAY module on the HOME page or the 2-WAY
button on the right panel of the OUT page, you will enter the configuration page.
or
The figure as below shows the setting page.
ACTIVE: When pressed, you will activate/inactivate the frequency filter (High Pass or
Low Pass). The activation can be realized by clicking the green letter A at the 2-WAY module
on the HOME page. The difference is that clicking the letter A will activate/inactivate
the High Pass Filter and the Low Pass Filter at the same time while clicking an ACTIVE
button on the setting page will only activate/inactivate the corresponding frequency filter.
FREQUENCY: Indicates the cut-off frequency of the filter.
TYPE: Filter types, including Butterworth filters, Bessel filters, and Linkwitz-riley filters.
SLOPE: Filter slope setting, optional 6dB/oct~48dB/oct.