Victron Energy EV Charging Station NS handleiding

38 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 33 van 38
VictronConnect code GX device code Generic code Message Instructions/Remarks
W-103 #103 103
EVCS high
temperature detected
Appears when a high
temperature is detected
in the EVCS box, but
the temperature is not
yet critical to stop
charging.
Remove EVCS from
direct sun light
or contact installer.
W-104 #104 104
GX communication
warning
Appears when
communication with GX
is enabled but not
present.
Check GX device IP
address and VRM
portal ID configuration.
W-105 #105 105 Overload detected
Appears when EVCS
detects overload.
W-106 #106 106 Overload active
Appears when EVCS
detects overload and it
is active.
W-107 #107 107
Scheduled mode
failed - time sync
issue
Appears when EVCS
can’t synchronise the
local date/time and
the user switches to
scheduled mode.
Notifications
VictronConnect code GX device code Generic code Message Instructions/Remarks
N-301 #301 301
Auto mode not
available
Appears when
attempting to set
Auto mode but
GX communication is
disabled.
Enable communication
with GX device.
N-302 #302 302
Scheduled mode not
configured
Appears when trying to
set Scheduled mode
but the scheduler is not
yet configured.
Add configuration for
Scheduled mode.
N-303 #303 303
Car disconnected -
can't start charging
Appears when the
'Start' button is pressed
but the car is not
connected to EVCS.
Connect the car.
N-304 #304 304 Charger error
Appears when the
'Start' button is pressed
but the EVCS has an
error.
Check errors and
resolve them; contact
the installer.
Manual - EV Charging Station NS
Page 30 Troubleshooting

Bekijk gratis de handleiding van Victron Energy EV Charging Station NS, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkVictron Energy
ModelEV Charging Station NS
CategorieNiet gecategoriseerd
TaalNederlands
Grootte4132 MB