Oil change
1.The hydraulic oil should be changed at least once a year. Sooner if it
appears dirty.
2.Unplug unit from power source. Remove oil plug and packing. Turn cutter
over and drain oil into a suitable receptacle. When oil ceases to drain out,
tilt unit to rear so that oil trapped in the piston housing can run out. When
housing is empty, tilt unit in the opposite direction to empty the residue in
the pump case.
3.With drain-hole uppermost, slowly fill the unit with fresh oil. Replace plug
and lightly tighten. Connect unit to power source and advance piston two or
three times. Unplug unit and remove oil-plug . Top up oil level and replace
plug.
4.Finally follow procedure for oil level check.
Note: Dispose of hydraulic oil in accordance with local regulations. Do not
pour into the sea, river, lake or drains.
Bolt tightness
Once a week or after every 500 cuts, check the tightness of all bolts,
especially those securing the housing to the cylinder. Loose bolts will result
in a loss of power.
Carbon brushes
Inspect the two carbon brushes at least once every two months. (normal
brush life is 200 hours.)
Care: Worn brushes will result in power loss, cause the motor to run hot
and irreparably damage the armature's commutator.
1.Disconnect unit
2.Unscrew both brush caps and pull out carbon brushes.
3.Replace brushes if less than 6 cm in lengh.