- 8 -
bender.Over and drain oil into a suitable receptacle.When oil ceases to
drain out, tilt unit to rear so that oil trapped in the piston housing can run
out. When housing is empty,tilt unit in the opposite direction to empty the
residue in the pump case.
2.With drain-hole uppermost, slowly fill the unit with fresh oil. Replace plug
And lightly tighten. Connect unit to power source and advance piston two
or three times.Unplug unit and remove oil-plug.Top up oil-level and replace
plug.
3.Finally,follow procedure for oil-level check.( Steps 2~8.)
Note: Dispose of hydraulic oil in accordance with local regulations. Do not
pour into the sea, river, lake or drains.
Bolt tightness
Once a week or after every 500 cuts, check the tightness of all bolts,
especially those securing the housing to the cylinder. Loose bolts will result
in a loss of power.
Carbon brushes
Inspect the two carbon brushes at least once every two months. (normal
brush life is 200 hours.)
Care: Worn brushes will result in power loss, cause the motor to run hot
and irreparably damage the armature's commutator.
1.Disconnect unit
2.Unscrew both brush caps and pull out carbon brushes.
3.Replace brushes if less than 6 cm in length.
Manufacturer: Shanghaimuxinmuyeyouxiangongsi
Address: Shuangchenglu 803nong11hao1602A-1609shi, baoshanqu,
shanghai 200000 CN.
Imported to AUS: SIHAO PTY LTD. 1 ROKEVA STREETEASTWOOD
NSW 2122 Australia
Imported to USA: Sanven Technology Ltd. Suite 250, 9166 Anaheim
Place, Rancho Cucamonga, CA 91730

Bekijk gratis de handleiding van Vevor NRB-32, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkVevor
ModelNRB-32
CategorieNiet gecategoriseerd
TaalNederlands
Grootte7533 MB