- 13 -
How to take out the water curtain and water tank :
1. Use a screwdriver to unscrew the fixing screw of the air inlet filter.
2. Slide the filter up from the body, remove the buckle and take out the air
inlet filter.
3. Two fingers are buckled from the upper part of the wet curtain, and then
take out the wet curtain downwards and backwards.
Clean air filter:
Pull off the plug, and pull the holder of air filter by hand while the air filter is
took apart .and then clean air filter by neutral cleaner and soft brush .and
then clean it by clean fair water , later take the air filter back air cooler.
•Clean the wet curtain paper:
Pull off the plug, and take the air filter off, and take the wet curtain paper
out air cooler. And clean the wet curtain paper by fair water after clean it
with cleaner and soft brush, later put back air cooler.
Important:
In order to avoid leak, wet curtain paper must be installed smoothly.
Clean water tank:
Pull off the plug, and take the water tank out while wipe off much scale in
the water tank by towel with little cleaner, and then clean water tank by fair
water, and later put back air cooler.
Clean the housing :
Wipe off the housing by neutral cleaner and soft cloth.
Important:
When clean the air cooler, the client must pull off the plug and cut off the
power while any part of control panel cannot be into water.