- 9
-
CHARGING FAULT DESCRIPTION
4. Charging indicator LED indicator status table.
4.1 Fault display description(EV-B07-EU011B/ EV-B07-EU022B)
4.2 Ground Fault: The ground wire is not connected or the ground wire
is poor. When this alarm message appears, please check if the grounding
is normal. After ensuring reliable grounding, press the H button for 5
Device Status
Three-color indicator status (green light: standby,
yellow light: charging, red light: failure)
Standby mode Green light steady on
The gun has been fired Steady yellow light
The gun is charging Yellow light flashing
CP fault The red light is on
Overpressure and
underpressure
The red light flashes once per second
The PE cable is not
connected
The red light flashes once in two seconds
Over-Current The red light flashes every four seconds
Electrical leakage of
equipment
The green and red lights flash once every second
Equipment
overtemperature
The green and red lights flash every two seconds