Table 2 Inverter Mode Specifications
INVERTER MODEL
3.5KVA
PVmax=160V
5.5KVA
Rated Output Power
3.5KVA/3.5KW
5.5KVA/5.5KW
Output Voltage Waveform
Pure Sine Wave
Output Voltage Regulation
230Vac±5%
Output Frequency
60Hz or 50Hz
Peak Efficiency
94%
Surge Capacity
2* rated power for 5 seconds
Nominal DC Input Voltage
24Vdc
48Vdc
Cold Start Voltage
23.0Vdc
46.0Vdc
Low DC Warning Voltage
Just for AGM and Flooded
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50%
22.0Vdc
21.4Vdc
20.2Vdc
44.0Vdc
42.8Vdc
40.4Vdc
Low DC Warning Return
Voltage
Just for AGM and Flooded
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50%
23.0Vdc
22.4Vdc
21.2Vdc
46.0Vdc
44.8Vdc
42.4Vdc
Low DC Cut-off Voltage
Just for AGM and Flooded
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50%
21.0Vdc
20.4Vdc
19.2Vdc
42.0Vdc
40.8Vdc
38.4Vdc