- 10 -
before breaking into the system or conducting any hot work. A degree of
ventilation shall continue during the period that the work is carried out. The
ventilation should safely disperse any released refrigerant and preferably
expel it externally into the atmosphere.
• Where electrical components are being changed, they shall be fit for the
purpose and to the correct specification. At all times, the manufacturer's
maintenance and service guidelines shall be followed. If in doubt, consult
the manufacturer's technical department for assistance.
• Detection of flammable refrigerants: Under no circumstances shall
potential sources of ignition be used in the searching for or detection of
refrigerant leaks. A halide torch (or any other detector using a naked flame)
shall not be used.
Defrosting
Defrost for better freezing efficiency when the frost film in the cabinet is
5mm/1/5’’ thick.
When defrosting, turn off the power, take out the frozen foods, open the
door for warming and melting. Use soft cloth to absorb water and clean it
up.
Extract the water conduit and put in a water container
Do not use sharp metal tools such as steel brush to clean the frost film
when defrosting so as to avoid evaporator damage.
Never use hairdryers, electrical heaters or other such electrical appliances
for defrosting.
When defrosting has finished drain the water in the bottom of the freezer
by removing the cap, as illustrated below.
There is a water conduit at the bottom of the freezer, when defrosting,
extract the rubber cover, the defrosted water will drip into the hole and flow
out.