Vevor 90E handleiding
Handleiding
Je bekijkt pagina 18 van 160

- 17 -
Failure and exclusion
Trouble
Reason
Remedy
No welding
output
1. Connected power supply
incorrectly.
2. Power switch in off position
1. Connect power supply
according to manufacturer's
instructions.
2. Place power switch in “on”
position.
Trigger not
working
1. Trigger damaged.
2. Gun control wire broken.
3. Control wire plug loosen.
4. Mode switch in incorrect
position.
1. Replace trigger.
2. Connect again or replace
if necessary.
3. Connect control wire plug
again.
4. Place Mode switch in
correct position.
Poor weld
1. Amperage too low
2. Input power cord did not
meet the requirement.
3. Ground clamp bad contact.
1. Increase amperage setting
2. Replace input power cord.
3. Change ground clamp
location.
Piercing
workpiece
1. Output amperage too high
2. Bad contact of electrode
tip or washer with workpiece.
1. Reduce amperage setting
2. Remove coating from
material reduce added
pressure.
Carbon rod
working
unstable
1.Carbon rod or workpiece is
dirty.
2.Incorrect amperage and
time setting.
1. Polish carbon rod and
workpieces
2. Set amperage and time
according to workpiece
thickness
Unit stop
working while
operation
1.Trigger plug loosen.
2.Gun control wire broken.
3.Over heating.
1. Check gun control wire
and trigger plug.
2. Wait for temperature cool
down
Maintenance and repair