Vestil WL-100-8-610 handleiding
Handleiding
Je bekijkt pagina 17 van 30

Operator’s Manual Rev. 6/11/25 WL-100 MANUAL 06-25.DOCX
Table of Contents Copyright 2023, Vestil Manufacturing Corp. Page 17 of 30
INSTALLATION INSTRUCTIONS
Review this entire section before installing the Dock Lift.
Consult the factory in the event of questions or problems at the time of installation.
Modifications or additions to the Lift, without prior authorization by the manufacturer, automatically voids the
warranty. See ANSI standard MH29.1-2003, Safety Requirements for Industrial Scissor Lifts, Section 12.6. Attaching
ancillary equipment to the platform will lower its load capacity.
The installation shall comply with all applicable regulations for its location and use.
The end user is responsible for verifying that this lift table and its installation are suitable for its environment and
application.
An architectural or engineering review of the planned installation is recommended.
This Lift shall be installed only by qualified and trained personnel with access to appropriate equipment. Electrical
connections shall be performed by a qualified electrician.
Before You Begin.
The Dock Lift must be anchored to a smooth, level, and adequately strong concrete surface.
For pit installations, first determine where and how the electrical and/or hydraulic connections will be made when
the Lift is in place. Reference the PIT DIAGRAM and dimensions table to plan your installation.
For installations using an approach ramp, ensure that there is adequate clearance beyond the ramp for equipment
using the ramp, such as forklifts or pallet trucks.
Tools And Supplies.
The following tools and supplies may be needed to install your Dock Lift. These items are not supplied with the
product.
A fork truck or hoist and rigging, capable of unloading the Dock Lift and setting it in place. Weights vary from
2800 lb to 6700 lb, depending on model.
A masonry drill and bits; hand tools, grout, and steel shims.
A smooth, level concrete surface on which to mount the Scissor Lift.
Eight ؾ” concrete anchors. The customer is responsible for selecting anchors appropriate for the Dock Lift
model and concrete floor conditions. DO NOT operate an unsecured Scissor Lift.
Five wires, 18 AWG or larger, or an appropriate hard service cable, 8 feet long. These connect the power unit
enclosure to the Dock Lift frame.
A power supply and electrical disconnect matching the pump motor’s voltage and current requirements. Refer
to the Dock Lift’s data plate, labels on the control enclosure, and the electrical diagrams in this manual for more
information. The end-user is responsible for supplying the required ground-fault and short-circuit protection on
the supply. Motor overload protection is provided by a thermostat built into the motor.
For pit installations, a minimum 2” conduit installing in the pit wall or floor to allow wire and hose access.
Electrical lines are low-voltage (24 VAC), and may share a conduit with the hydraulic lines except where
prohibited by local codes. Conduit shall have a minimum bend radius of 10”. A pit drain should be installed. The
end-user is responsible for purchasing materials and constructing the pit.