11-3-1 Film-seat motor brake (BK2) not working   
Condition: 
a). Relay RYBK2 is working on PC board KS-050201-MB and LED BK2 would light up. 
b). Fuse F1 (2A) on PC board KS-050201-MB is normal. (If a fuse F1 was blown, red LED BK2 
Fuse fail on PC board KS-050202-KEY would light up.) 
  Check if brake B2+ and B2- contain 
DC24V.  
YES 
  Replace brake BK2.   
       NO 
  Check if there’s DC24V at terminal 0V and 
24V of CN9 on PC board KS-050201-MB.   
 YES
  Replace Relay RYBK2   
       NO 
  Refer to1-3, check if switching power 
PS-65-24 is working.   