Vestil SWA-60-AW handleiding
Handleiding
Je bekijkt pagina 51 van 88

F:\Manual\SM-1517R-110V-100514    14.05.2010. 
- 48 -
11-1-3 There isn’t DC24 Volt. on power supply PS-65-24 
  Refer to PC board PS-65A, check if there’s 
DC24V at P1 and P4 on CN2. 
YES 
  Replace connection cord CN9. 
       NO 
  Check if FUSE F1 on PC board PS-65A is 
blown. 
 YES
  Replace FUSE.   
       NO 
  Refer to PC board PS-65A, check if there’s 
AC220V at P1 and P2 on CN1. 
YES 
  Replace PC board PS-65A.   
       NO 
  Check if there’s AC110V at term inal L12
and L22.   
YES 
  Replace FUSE F3 and F4(3A).   
       NO 
  Check if there’s AC110V at term inal L11 
and L21. 
YES 
  Replace Line Filter.   
       NO 
  Check if input power voltage is normal. 
YES 
  Replace Main Power Switch.   
Bekijk gratis de handleiding van Vestil SWA-60-AW, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.