Vestil SSLP-200-2 handleiding

7 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 5 van 7
Table of Contents
Rev. 7/23/2020.
SSLP-200-2 MANUAL
Table of Contents
Copyright 2020 Vestil Manufacturing Co.
Page 5 of 7
LOAD TESTS
After creating a RECORD OF SATISFACTORY CONDITION and before putting the lifter into service,
a
qualified person should conduct a load test. The test load should be 125% of the rated load of the lifter,
i.e. 25,000 pounds (11,364kg). Raise the test load until it is suspended a few inches above the ground.
Return the lifter to the ground and unload it. Perform a Monthly Inspection as described in INSPECTIONS
AND MAINTENANCE (below). The lifter must undergo load testing immediately after it is repaired,
modified, or altered.
INSPECTIONS & MAINTENANCE
Inspection procedures are included in ASME standard B30.20. As stated above in the NATIONAL
STANDARDS section, Vestil recommends that you acquire a copy of the most recent
revision of this
standard. Apply all use and maintenance/care instructions in it. Vestil also recommends that you
contact your local occupational safety and health authority to determine if any laws, regulations,
codes, ordinances, etc. apply inspection requirements to below-the-hook lifters.
Inspections and repairs should only be performed by qualified persons. Compare the results of each
inspection to the RECORD OF SATISFACTORY CONDITION (the “RECORD”). Do not use the lifter
unless all parts are in satisfactory condition. Replace parts that are not in satisfactory condition before
using the lifter again. DON’T GUESS! If you have any questions about the condition of your lifter,
contact the TECHNICAL SERVICE department. The phone number is provided on the cover page of
this manual. Never make temporary repairs of damaged or missing parts. Only use manufacturer-
approved replacement parts. Deformities, cracks, and severe wear of the lifting arm or main body requires
immediate replacement of the entire unit.
Every lift
The operator of this lifter must inspect the lifter before each use. Look for cracks, warps, and other
forms of damage. Clean dirt or other surface debris off of the lifter. Tighten the shackle pins.
Monthly Inspections
At least once per month a qualified person must perform the following inspections. Written reports
should be prepared for every monthly inspection including inspections following LOAD TESTS.
1.
Frame (08-014-237): Examine each pin/bolt hole and the surrounding metal for elongations, cracks,
rusting and corrosion. Pin holes should be smooth and circular. Make sure that the metal around the
pin/bolt holes is not cracked, warped, thinned, or rusted/corroded.
2.
The frame should be square and rigid. There should be no cracks, warps, regions weakened by severe
rusting or corrosion, etc.
3.
Fasteners: Inspect the shackle bolt, nut, and cotter pin. The bolt must be straight and must have no
cracks,
warps, etc. Tighten the nut. Confirm that the cotter pin is in place and undamaged.
4.
Load shackles and top shackle: Examine each shackle for damage including significant wear, warping,
cracks, or deformation. Measure the throat opening of each shackle.
Compare these measurements to
the measurements in the RECORD. The throat opening of each shackle should not be 15 percent or
more in excess of normal throat opening or be twisted more than 10° from the plane of the unbent
shackle.
5.
Labeling: Labels should be readable and attached in the locations shown in the LABELING DIAGRAM.
If a label is unreadable, damaged, or missing, contact Vestil to order a replacement.