ROUBLESHOOTING:
Before performing any corrective action described in the following table, block the drive
wheel off of the ground.
Contact Vestil for problems at time of installation, or for any problems not addressed below.
Problem: Possible cause(s): Action:
Unit does not respond to
movement controls (does not
move either forward or in
reverse).
Battery voltage low (battery
charge lower than 17 Volts)
Problem with motor controller
(check for LED flash code on
side of controller)
Fuse blown
Charge batteries.
Bad batteries; load test batteries
and replace if necessary.
Consult diagnostics
Troubleshooting Chart; or Refer
to 15-124-029 electrical drawing
for pro
per voltage readings and
operation; or Consult Factory
Unit will not charge Charger malfunction
Bad batteries
Remove back shroud and check
fuses.
Verify output voltage on charger,
it should be
26 to 30 volts, dc,
connected to batteries, and
plugged into 115vac.
Load test the batteries
Unit will not go forward; reverse
works; belly switch just kills unit
(does not go forward and faults
out)
Broken wire, or loose connection
Contactor bad, motor controller
bad
Locate Pin 2 on Molex connector
at motor controller. Trace wiring
to contactor and verify
connection.
While attempting to go forward,
tap on the contactor with a
screwdriver handle. If the unit
moves forward, then the
contactor may need replaced, or
plungers lubed with a light oil.
Remove both wires from each
side of the contactor, and check
with ohm meter; resistance
should be approximately 38
ohms. If it’s open or zero, the
contactor should be replaced.
Consult diagnostics page Table 2
Troubleshooting Chart; or Refer
to 15-124-029 electrical drawing
for proper voltage readings and
operation; or Consult Factory.
Unit will not go reverse; belly
switch works (i.e. when the
handle is in operating range and
rotating throttle in reverse and
the belly switch is hit, the unit
moves forward and times out)
Broken wire, or loose connection,
contactor bad, motor controller
bad
Same as above; except locate
Pin 3 on Molex connector on
motor controller…and follow
procedure.
Copyright 2017 Vestil Manufacturing Corp.
Page 12 of 13
Copyright 2017 Vestil Manufacturing Corp.
Page 9 of 13
SNM-90-AA, Manual.doc
Unit will keep raising and will not
stop until E-Stop button is
pushed down.
Pin inside the switch is sticking
1- Replace the switch
2 - Take the handle cover off and
push the pin on the swithc.
3 - Lube the area around pin.