Inspections:
If one or more problem is discovered during an inspection, restore the table to normal
operating condition BEFORE using it again. DO NOT use a boom that is structurally damaged in any way.
Structural damage includes, but is not limited to, cracked welds, warping or deformation of the fork pockets,
support leg, frame members, boom, boom sleeve, hooks or shackles.
DO NOT inspect the unit or perform any repairs or maintenance on the table unless it is properly tagged out and
the deck is immobilized:
1. Unload the table.
2. Raise the deck to its maximum height. Insert the maintenance prop between the scissor leg rollers
and the end of the frame.
3. Lower the deck until the deck lowers no further and the rollers rest against the maintenance prop.
(A) Before Each Use Check For Any of the Following Conditions:
Oil leaks
Pinched or chafed hoses
Deformation of legs, frame, and deck
Unusual noise or binding
(B) Monthly Inspections:
1. Determine the oil level. Oil should be 1" to 1-1/2" below the top of the reservoir/tank with the deck
fully lowered. Add oil, if necessary.
2. Check for oil leaks (see "Troubleshooting" on p. 11). Resolve the issue as described.
3. Check roller bushings, axle pins, clevises and pivot points for severe wear.
4. Check the hydraulic system for worn or damaged hoses. Replace damaged hoses as necessary.
5. Inspect each roller for looseness and severe wear. See "Troubleshooting" on p. 11.
6. Examine the retaining rings at all axles, pivot points and clevises.
7. Cycle the deck and listen for unusual noise. See "Troubleshooting" on p. 11.
8. Make sure all labels are in place and in good condition, as shown in the label placement diagram on
p. 11.
9. Clean dirt and debris from all surfaces of the table.
(C) Yearly:
Change the oil at least once a year or sooner if it darkens, is gritty, or appears milky. Milky appearance
indicates the presence of water. Replace the oil with AW-32 hydraulic fluid or its equivalent.
Maintenance:
The end-user should implement a maintenance program to ensure that the product functions properly. The
following steps should be utilized in conjunction with inspections.
Step 1: Tag the boom, “Out of Service.”
Step 2: Remove any dirt or other matter from all surfaces.
Step 3: Conduct a “Before each use” inspection. If deformity, corrosion, rusting, or excessive wear of structural
members is found, DO NOT use the product.
Step 4: Perform all other necessary adjustments, replacements and/or repairs. DO NOT modify the boom.
NOT use the table if adjustments and repairs are incomplete! Return it to service ONLY after
finishing all necessary repairs and adjustments. The reader should understand the significant difference between
necessary adjustments and repairs, and modifications.
An “adjustment” is a simple correction that restores the boom to normal operating condition, such as tightening
loose fasteners, or removing dirt or other debris from the surface. “Repair” refers to removing worn parts and
installing replacement parts.
A “modification” is a change that alters the table from normal operating condition, like bending the frame
members or removing parts. NEVER modify this product. Modifications automatically void the limited warranty
and might make the table unsafe to use.
Step 5: Make a dated record of all repairs, adjustments and/or replacements made to the table.