INSTALLING THE DRUM DUMPER
NOTE: Only Applies to Stationary Units HLD-94-10-S, HLD-94-15-S, HLD-116-10-S, HLD-116-15-S.
Responsibility for complying with local building code requirements, municipal/county ordinances,
state OSHA requirements, etc. rests exclusively with the end-user. The instructions that appear below are
recommendations about essential, minimum steps necessary for safe installation. If law enforced where
the dumper is used requires you to depart from these directions, Vestil is not responsible for any
consequential damages sustained as a result of the installation.
Installation requires the following equipment, tools, and materials:
• Forklift rated for loads equal to the net weight of your HLD model. See Specifications document
• Lag bolts: ½ in. by at least 4in. (length) [approximately equivalent to 1.3cm by at least 10.2cm]
• Masonry drill and ½ in. masonry drill bit
• Wrench: ½ in.
• Grout and steel shims
• Power supply circuit matched to motor voltage and current requirements
NOTE: The end-user is responsible for providing over-current and short circuit protection. Refer to the
appropriate ELECTRICAL CIRCUIT DIAGRAM
on p. 10-12.
Step 1: Position the dumper as desired with a forklift.
Step 2: Drill holes approximately 4in. (10cm) deep.
Step 3: Secure the dumper to the floor by
inserting the lag bolts through the (5/8 in.) bolt
holes in the anchor brackets (dotted lines in
FIG. 1).
Step 4: Shim and/or grout the sides of the
frame.
Step 5: Connect the power cord to the power
supply.
Step 6: Read the OPERATING THE DRUM
DUMPER section of this manual on p. 5. Then,
cycle the dumper all the way up and back
down. Press the LIFT RAISE button of the hand
controller until the chute reaches its maximum
elevation. Then, press the TILT RAISE button
until the chute tilts as far as it can. Return the
chute to the upright position by pressing the
TILT LOWER button. Lower the chute to the
home position by pressing the LIFT LOWER
button.
Step 7: Check the oil level in the reservoir. Fully raise the chute (to the 45°) “dumping position,” and then
observe the level of oil in the reservoir. The surface of the oil should be 1 to 1½ inches below the fill hole.
RECORD OF SATISFACTORY CONDITION (THE “RECORD”)
Before putting the unit into service, record its condition. Thoroughly photograph the unit from
multiple angles. Include close range photographs of the drum clamps, pivot points, labeling, the chute,
frame elements, and casters/wheels (HLD-##-##-P units) or floor anchoring sites (HLD-##-##-S
stationary units). Use the handheld controller to raise and lower, and tilt and un-tilt the chute. Describe
the motion of the chute, e.g. smooth and at a constant rate, as well as sounds produced by the power
unit, the frame, and at pivot points. Remove the cover of the power unit and photograph the internal
components. Collect all photographs and writings into a single file. This file is a record of the unit in
satisfactory condition. Compare the results of all INSPECTIONS
to this record to determine whether the
unit is in satisfactory condition. Do not use the dumper unless it is in satisfactory condition. Purely
cosmetic changes, like damaged paint/powdercoat, do not constitute changes from satisfactory
condition. However, touchup paint should be applied to all affected areas as soon as damage occurs
to prevent rusting and/or corrosion from occurring.
FIG. 1: Installation diagram
Bekijk gratis de handleiding van Vestil HLD-116-10-S, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Vestil |
Model | HLD-116-10-S |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 5109 MB |